Bangkok, Thailand
![]() |
Image courtesy of Bumrungrad Hospital |
Client : Bumrungrad International
|
Building C comprises two attached towers and total net floor area of approximately 28,400 m2. The refurbished purpose of this building is to be predominantly office space.
EEC Lincolne Scott was initially appointed to assess the condition of the existing MEP infrastructure in Building C, and to make recommendations for improvements as the building was to be repurposed and refurbished from accommodation to offices. Following the completion of this scope of works, EEC Lincolne Scott was engaged in the design of the upgrade works including mechanical, electrical, sanitary, fire protection and vertical transportation systems.
The twenty year old buildings services and architectural design were not suitable for the refurbishment plans, out-dated and in some cases would no longer meet the requirements of current industry codes and standards. The equipment had not been upgraded since initial installation, and a lot of the technology was out-dated and by today’s standards inefficient.
The existing ventilation systems and split air conditioning systems, though still functional, would not meet current efficiency code requirements and did not provide good indoor air quality. The systems were removed and energy efficient VRF systems were installed. This allowed the total number of condenser units to be reduced significantly.
Outdoor air pre-cooling units were also installed on each floor.
As the previous use of the building was for accommodation, the conversion to offices increased the building loads and the electrical systems were upgraded to meet this increase. This involved installation of an additional transformer, MDB and new electrical distribution system. Lighting was also updated to meet Standards and be suitable for office space.
Temporary water and power supplies were installed to allow the building to remain partially occupied during the refurbishment.
Upgrades to the fire protection system were required to meet code. Additional fire water tank capacity was required but rather that just installing a new tank in the basement, EEC Lincolne Scott was able to make use of capacity in an oversized roof tank. Out-dated fire hose racks were replaced to comply with current regulations.
..........................................................................................................................
About us
Our Story
Our Philosophy
Project Collaboration Philosophy
Delivery Strategy
Our Team
Service
Civil and Structural
Air conditioning and Ventilation
Electrical and Communications
Fire Protection
Plumbing and Hydraulics
Vertical Transportation Services
Sustainable Design Services
Building Information Modelling : BIM
Project
Showcase Our Work
List of Project
EEC LINCOLNE SCOTT CO.,LTD.
42 EEC Academy 2 Building, Soi Ram Inthra 97, Khan Na Yao, Khan Na Yao District, Bangkok 10230 Thailand.
Google Earth / Map
Tel : +66 2130 4599
Fax : +66 2130 4594
[email protected]